Desktop Insertion Loss and Return Loss Tester

 

                        

 

 

 

 

图形1

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Insertion Loss and Return Loss Tester with color screen

 

图形1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


1. Outlines

Desktop Insertion Return Loss Tester with color screen has stable and reliable performance, which integrates stable light source, high-precision power meter, insertion loss meter and return loss meter into one multifunction instrument. Based on domestic customers’ requirements, R&D team combined advantages of same type instrument within China/overseas and then developed the high-precision tester by several years’s unremitting effort. With high cost effective and state of art characteristics, it can be widely used for OEM device verification, research institutions R&D and construction maintenance in optical fiber/passive devices/optical communication system industries where demand plug loss, return loss and stability measurements

 

Advantages:

l  Advanced OS

Multiple display, easy handling, fast response and stability

l  High precision

Stable output power/high detection speed/wide measurement range

l  Wavelength synchronous switching

l  Light source and power meter achieve wavelength synchronous switching under insertion/return loss mode

l  Multiple working modes

Return loss mode/insertion loss mode/power meter/dual-wavelength testing

l  Color recognition for test result

Different colors correspond different test results. Pass/Fail is available by just a glance. P

l  Easy handling

Return loss/insertion loss are synchronously measured. No buttons switching

l  Rich display interfaces

High definition LCD plus multi-level test interfaces bring rich visual experience and easing visual fatigue

l  Perfect outward design

Electro-magnetic proofing by metal covering. Durable buttons bring comfortable finger handling experience

l  Smart removable interfaces of light source and power meter

Easy to be disassembled to clean optical detector or replace with others adapters(FC/SC/ST/2.5mm general/1.25mm general/MT-RJ) or clean inside APC adapter. Note only need to rotate light source/power meter interface to disassemble it

l  Clock display

Time is available to reasonably organize work

l  Communication interfaces

The tester can connect to computer and transmit test data to it. Specialized program give Pass/Fail result of jumper. Test data is available for analysis, readout and record.

 

2. Technical parameters

Model

Insertion and return loss   tester

Light source wavelength

MM850nm SM1310/1550nm

Optical return loss test

Wavelength

1310/1550nm

Measurement range

0~75dB

Calibration wavelength

1310/1550nm

Measurement tolerance

±0.4dB

Output stability

0.02dB /hour@250C)

Interface types

MM:850nm FC/UPC SM: 1310/1550nm FC/APC

Optical insertion loss test

Calibration wavelength

850/980/1300/1310/1490/1550/1625nm

Measurement range

+3~-80dBm

Measurement tolerance

±0.03dB

Display resolution

Logarithmic: 0.01dB; linear:   0.001nW/μW/mW

Test mode

Linear and non-linear

Interface types

Removable: FC/SC/ST/generalΦ2.5mm/ generalΦ1.25mm adapters


Screen

Color LCD

Resolution

320*240

Communication interface

USB

Power supply

AC 90-260V

Work environment

temperature-50C~+550C  ;humidity<95%RH No condensation

Storage environment

temperature-200C~+700C  ;humidity<85%RH No condensation

Dimensions

265X265X140mm

Weight

3.5kg

 

 

3. Instruction of buttons on the panel

(1)    λ: switch of light source wavelength

(2)    Ref: calibrate return loss reference value-----long time press

(3)    BL:clear button for return loss     

(4)    dBm/dB: clear button for insertion loss

(5)    Set: Set up or conversion

(6)     +: increase

(7)    –: decrease

(8)    Enter : confirm

(9)    850nm850nm multimode light source outputFC/UPC

(10)1310/1550nm1310/1550nm single mode light source outputFC/APC

    (11)Power meter interface

 

4.Function introduction

 

 

l   Default     mode is insertion/return loss after tester power is on

l   1310nm/1550nm     insertion and return loss as well as 850nm plug loss can be measured under     the default mode

l   Press λ     button to switch light source wavelength

l   Press     BL button to clear return loss

l   Press     dBm/dB button to clear insertion loss

 

 



 

l   Setup     interface includes the followings: pattern/threshold/time/lang-uage     settings, restore factory settings, system information and exit menu

l   Press     Set to move the cursor. Press Enter to confirm

l   When     the cursor moves to one line, press Enter to go to its sub-menu

l   When     the cursor moves to Exit, press Enter to go to its upper level menu

 

 


 

 

 





 

l   Test     modes(insertion/return loss mode, power meter mode and dual wavelength     mode) are optional under the interface showed on the left

l   Press     Set to move cursor onto the mode, then press Enter to pop up optional list.     Again press Set to move cursor and press Enter to select the mode

l   Press     Confirm to save options and return to Setup interface

l   Press     Return to discard options and return to Setup interface

 

 

 

 



 

 

 

 


 

l   Enter     into power meter mode interface by mode selection

l   Under     this mode, power and insertion loss of the following wavelengths can be     tested:

850nm980nm1300nm1310nm1490nm1550nm

1625nm

l   Press     λto switch the wavelength of power meter

l   Press     dBm/dB to clear insertion loss

l   Press     Set to return to setup interface

 

 


 


 

l   Enter     into dual wavelength mode interface by mode selection

l   Under     this mode, the insertion loss and return loss of 1310nm/1550nm can be     measured and revealed simultaneously

l   Press λ     to switch the wavelength of light source

l   Press     BL to clear return loss

l   Press     dBm/dB to clear plug loss

l   Press     Ref to finish 14.8db calibration of return loss

l   Press     Set to return to setup interface

 

 

 


 

 

 

 


 

l   Enter     into threshold interface mode by mode selection

l   Under     this mode, the threshold value range for color discriminnation of the     insertion loss and return loss can be set

l   Press     Set to move cursor. Press +/- to increase/decrease threshold value.(long     time press +/- will 10 times increase/decrease it)

l   Press     Confirm to save options and return to Setup interface

l   Press     Return to discard options and return to Setup interface

 

 


 

 

 

 


 

l   Enter     into time-setting interface by mode selection

l   Under     this mode, the        year/month/day/hour/minute     can be set

l   Press     Set to move cursor. Press +/- to modify

l   Press     Confirm to save options and return to Setup interface

l   Press     Return to discard options and return to Setup interface

 

 



 

l   By setting the interface into the     language setting interface

l   This interface can be carried out in     English switch

l   Press the Set key to move the cursor to     the language, press the Enter key to display the selected language list,     press the Set key to move the cursor, and then press Enter key to confirm     the mode choice of language

 

 

 


 

 

 

 


 

l   Press     Set to move cursor onto “restore factory settings” under setup interface

l   Press     Enter to restore to factory settings

 

 


 

 

 

 


 

l   Enter     into product information under setup interface

l   Product     model/software version/manufactured date/SN are showed under product     information interface

l   Each     product(or tester) has a sole SN as its identity

 

 

 


 

 

5.Operation explanation

 

(1)   Select standard jumper according to the jumper to be tested. If the tested jumper is PC end, select the jumper APC-PC; If the tested jumper is APC end, select the jumper APC-APC.

 

 

 

 

 

 

 

 

(2)   Zero the return loss of optical channels before the measurement. Press Laser key to switch wave length of light source, connect APC end (say starting end) of the jumper to light source output port, wind the other end (the closing end) of the jumper using the winding bar, the moment the optical power value of the return loss channel should be -60dBm to -70dBm, then press Zero. To measure double wave length, press Laser key to switch the wave length of light source, then press Zero.

 

 

 

 

 

 

 

 

 

 

(3)   Identify the return loss of optical channel before measurement. Release the winded jumper and make the jumper extend up. Insert the end of the jumper into the interface of optical power meter, press Ref. To measure double wave length, press Laser key to switch the wave length of light source, then press Ref.

 

 

 

 

 

 

 

(4)   Zero the return loss of optical channels before the measurement, press dB/w. To measure double wave length, press Laser key to switch the wave length of light source, then press dB/w.

(5)   Measure the insertion loss at the end of jumper. Connect the end of jumper and the tested end (starting end) of the jumper to be tested using standard flange, insert the other end (closing end) of the tested jumper into the interface of optical power meter. To measure double wave length, press Laser key to read the insertion loss values of the other wave length.

 

 

 

 

 

 

 

(6)   Measure the return loss at the end of jumper. Wind the jumper near the starting end of the jumper to be tested using the winding bar. The moment the measurement value of return loss appearing in return loss area is return loss value at the starting end of the jumper to be tested. To measure double wave length, press Laser key to read the return loss values of the other wave length.

 

 

 

 

 

 

 

(7)   To proceed to the next test, repeat steps (5), (6).

(8)   If you need to replace the standard jumper, repeat the above operations from step (1). If you don’t need to replace the standard jumper, even if the tester has been restarted after power-off, you will only need to repeat steps (5), (6).

 

Color recognition instruction

Under threshold value setting interface, set reasonable values according to requirements. Green color rbepresents PASS; Red color represents NG

For example. ”plug loss: 0.00dB-0.30dB” implies the value within -0.3dB will show green color, otherwise red color; “return loss: 50dB” implies the value above 50 will show green color, otherwise red color

 

6.Precautions and maintenance

(1)   Forbidden to directly look at laser output interface and optical jumper interface by naked eyes to avoid eyeball and skin hurts

(2)   Forbidden to use unmatched optical fiber to connect laser output interface which can damage it and degrade the whole tester performance

(3)   Clean all optical fiber interfaces with special tools before use

(4)   Minimum length of standard jumper is 1m

(5)   Diameter of winding rod is between 3~5 mm. Minimum winding turns is 5

(6)   Keep sensor interface clean. Do not use dirty or non-standard adapter or poor polishing interface. Otherwise it will damage sensor interface and sharply degrade the whole tester performance

(7)   Suggest to use the same type adapter to minimize errors

(8)   Cover all interfaces with dust caps when tester is not used

(9)   Carefully handle optical adapter to avoid scratch

(10)    Periodically clean sensor. Use special swabs to slightly clean along circle direction

(11)    Power off tester and cover optical connector covers if no use. Keep tester in a dry    and ventilated place

(12)    Keep optical connector clean

(13)    Slightly handle tester to avoid collision or drop

(14)    Remove power plug if no use with a long time

(15)    Forbidden to disassemble tester. It will lose warranty and may bring permanent damage

 

 7.Quality declaration

 

(1)   Tester quality is guaranteed by standard jumper strict quality management. If there is quality issue or damaged during transportation, please contact with standard jumper

(2)   Warranty is 18 months since the delivery day. If there is any function disabled problem within warranty, standard jumper will provide free maintenance or exchange of product except:

a)  wrong handling by user

b)  disassembly by user

c)   damage caused by natural disasters

Under those cases, standard jumper will charge appropriate maintenance fee(not exceed the purchase price)

(3)   To avoid fire, electric shock or unknown risks, Forbidden to disassemble tester in any case even problems are still not resolved following FAQ

 

 

Appendix: FAQ

 

Abnormal plug loss value

1.Laser output   interface is loosen or worn out

2.   standard jumper is dirty or worn out

3.Photosensitive   interface inside power meter is dirty or worn out

4.Metal interface of   power meter is worn out

5.   standard jumper is out of spec.

6. Optical fiber core   of laser output is worn out

Abnormal return loss value

1. Laser output interface is loosen or worn out

2. standard   jumper is dirty or worn out

3. standard   jumper is out of spec.

Unstable laser source

1.No preheat   process(generally 5min~10min preheat is required)

2. Photosensitive   interface inside power meter is dirty

3.   standard jumper is worn out

4.   standard jumper is dirty during measurement.   Clean standard   jumper or make a clear operation

Wrong plug loss value

1.No clear operation

2.Retest

3.Under test fiber is   dirty or worn out

4.Adapter is loosen or   worn out

5.   standard jumper is out of spec. or worn out

6.Photosensitive interface   inside power meter is dirty or worn out

7.Metal interface of   power meter is worn out

 

Wrong return loss value

1.No clear operation   or clear fails to complete(Minimum winding turns is 5)

2.Under test fiber is   not correctly wound according with test instruction

3. Adapter is loosen   or worn out

4.   standard jumper return loss is out of spec.

5. Optical fiber core   of laser output is dirty or worn out

 

Return loss fails to clear

1.Wrong handling.   Please refer to test instruction

2.   standard jumper return loss is out of spec.

3.Wrong winding or   connector is loosen

4. Laser output   interface is dirty or worn out

5.   standard jumper interface is not matched

No laser output

1.Connect to a wrong output interface

2.Jumper is not   connected to power meter

3. standard   jumper is damaged

4.Laser output   interface is loosen

Wrong color recognition

1.No setting or save   for threshold value

2.Wrong setting for   threshold value

4.Measured data is out   of setting spec.

 

 

 

 

After this company, who agreed to this product without authorization tear open outfit, repair or modify and cause damage to the product, do not grant to maintenance.

                       

 

Since the purchase this product warranty period: the 18 months warranty for the product of the purchase, when in this period was found to have quality problem, the company will make the proper repair or replacement. But in any case, the company's responsibility is no more than the the product of the purchase price.

1.     In normal use this product and produce fault, the user can show warranty card and invoice or receipt (copy), can enjoy free maintenance services.

2.     If belong to any of the following circumstances, the user need to pay maintenance and transportation, materials and other related expenses

A)    In normal use this product and fault, but already more than warranty period range of products.

B)    The artificial damage, or high temperature, high pressure, such as wet conditions used

C)    Not to follow the instructions of the use method and points for attention and cause of the fault and damage.

D)    For manufacturing defects caused by fault. The company is responsible for the quality of free repair or replacement instrument, the guarantee applies only to the normal use of instrument, no damage and improper use or conditions.

 

 

Notes

This manual is only valid for the product it’s following. Technical specification or operation method may change without prior notice. Please check with distributor or OEM if necessary

 

standard jumper reserves all copyright. No duplication, adaption, translation or any other way transmission without written permission

 

    The tester power supply is designed according with industry standard. standard jumper has no responsibilities for any unstable tester performance or electric shock accidents caused by no connection to ground. Connection to ground is mandatory.